<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Engineering Geology</title>
<title_fa>نشریه زمین شناسی مهندسی</title_fa>
<short_title>Journal of Engineering Geology</short_title>
<subject>Basic Sciences</subject>
<web_url>http://jeg.khu.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2228-6837</journal_id_issn>
<journal_id_issn_online>2981-1600</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.22034</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1401</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2022</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<volume>16</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>شناسایی موقعیت‌های نشت با استفاده از اثر تغییرات رطوبت خاک بر شکل موج‌های TDR</title_fa>
	<title>Identifying leakage situations using the effect of soil moisture changes on TDR waveforms</title>
	<subject_fa>زمین شناسی مهندسی</subject_fa>
	<subject> Engineering Geology</subject>
	<content_type_fa>مقاله پژوهشی</content_type_fa>
	<content_type>Original Research</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family:yekanYW;&quot;&gt;&lt;span style=&quot;color:#000000;&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;span lang=&quot;FA&quot;&gt;روش&#8204;های الکترومغناطیس در ژئوفیزیک کاربردی به سرعت در حال پیشرفت هستند. از زمانی که روش بازتاب سنجی در حوزه زمان برای امواج رادار هدایت شده (&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;TDR&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;) رشد کرده &#8204;است استفاده از آن منجر به کاربرد خلاقانه و مقایسه آن با سایر روش&#8204;های اندازه&#8204;گیری قبلی شده است. یک سیستم &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;TDR&lt;/span&gt; از یک دریافت کننده و تولید کننده موج رادار (الکترومغناطیس)، یک خط انتقال و موج بر تشکیل شده است. پالس الکترومغناطیس تولید شده از درون کابل هادی به سمت موج&#8204;بر حرکت می&#8204;کند و از طریق موج بر وارد محیط تحت آزمایش می&#8204;شود هدف از این تحقیق این است که با انجام آزمون&#8204;هایی بر روی کابل&#8204;های مخابراتی دو رشته&#8204;ای به عنوان سنسور &lt;span dir=&quot;LTR&quot;&gt;TDR&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;، توانایی و دقت روش بازتاب سنجی زمان در تشخیص موقعیت&#8204;های نشت مورد ارزیابی قرار گرفته است. در این تحقیق کابل دو رشته&#8204;ای در زیر مصالح رس گراولی &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;GC&lt;/span&gt; مدفون شد و با افزایش درصد رطوبت خاک به صورت پله&#8204;ای در دو نقطه، حساسیت روش &lt;span dir=&quot;LTR&quot;&gt;TDR&lt;/span&gt; نسبت تغییرات رطوبت در اطراف کابل، مورد بررسی قرار گرفت. بر اساس شکل موج&#8204;های &lt;span dir=&quot;LTR&quot;&gt;TDR&lt;/span&gt; نقاط تغییرات ثابت انعکاس در فاصله&#8204;های 9-9/5 و 4/5 متری قرار دارد که کاملاً با فاصله واقعی نقاط آزمایش انطباق دارد. در این پژوهش از دستگاه رطوبت سنج &lt;span dir=&quot;LTR&quot;&gt;TDR&lt;/span&gt; ساخت شرکت &lt;span dir=&quot;LTR&quot;&gt;soil moisture&lt;/span&gt; مدل6050 &lt;span dir=&quot;LTR&quot;&gt;x1&lt;/span&gt;&lt;span lang=&quot;FA&quot;&gt;&amp;nbsp; استفاده شده است. نتایج این پژوهش نشان می&#8204;دهد که روش &lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;TDR&lt;/span&gt; توانایی آن را دارد به عنوان یک سیستم مانیتورینگ برای تشخیص محل نشت در سدها، دایک&#8204;ها و سایر سازه&#8204;های ژئوتکنیکی به کار برده شود.&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-family:&quot;Calibri&quot;,sans-serif&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family:yekanYW;&quot;&gt;&lt;span style=&quot;color:#000000;&quot;&gt;Electromagnetic methods in applied geophysics are advancing rapidly. Since the TDR system has grown, its use has led to innovative applications and comparisons with other previous measurement methods. A TDR system consists of a radar (electromagnetic) receiver and generator, a transmission line, and a waveguide. The electromagnetic pulse generated from inside the conductor cable moves towards the waveguide and is tested through the waveguide into the environment under test. In the last few years, the use of the TDR system to identify water leakage situations has been expanding. In this article, by performing tests on two-strand telecommunication cables as TDR sensors, the ability and accuracy of the time domain reflectometry method in detecting leakage situations has been evaluated. In this research, the two-stranded cable was buried under GC gravel clay material, and by increasing the percentage of soil moisture stepwise at two points, the sensitivity of the TDR method to the changes in moisture around the cable was investigated. Based on the TDR waveforms, the points of reflection coefficient changes are located at the distances of 9.5-9 and 4.5 meters, which is completely consistent with the actual distance of the test points. In this research, TDR moisture meter made by soil moisture company model 6050x1 was used. The results of this research show that the TDR method has the ability to be used as a monitoring system to detect leakage in dams, dikes and other geotechnical structures.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract>
	<keyword_fa>بازتاب سنجی دامنه زمان, پالسTDR , کابل دو رشته‌ای, نشت</keyword_fa>
	<keyword>Double Strand Cable, leakage, TDR Pulse, Time Domain Reflectometry, TDR.</keyword>
	<start_page>1</start_page>
	<end_page>15</end_page>
	<web_url>http://jeg.khu.ac.ir/browse.php?a_code=A-10-1069-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>kamal</first_name>
	<middle_name></middle_name>
	<last_name>ganjalipour</last_name>
	<suffix></suffix>
	<first_name_fa>کمال</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>گنجعلی پور</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>kganjalipour@gmail.com</email>
	<code>10031947532846006162</code>
	<orcid>10031947532846006162</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Markazi province regional Water Company</affiliation>
	<affiliation_fa>آب منطقه ای مرکزی</affiliation_fa>
	 </author>


	<author>
	<first_name>Mahmoud</first_name>
	<middle_name></middle_name>
	<last_name>Fatemi aghda</last_name>
	<suffix></suffix>
	<first_name_fa>محمود</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فاطمی عقدا</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>fatemi@khu.ac.ir</email>
	<code>10031947532846006163</code>
	<orcid>10031947532846006163</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Kharazmi University, Tehran</affiliation>
	<affiliation_fa>دانشگاه خوارزمی تهران</affiliation_fa>
	 </author>


	<author>
	<first_name>kamal</first_name>
	<middle_name></middle_name>
	<last_name>nabiollhi</last_name>
	<suffix></suffix>
	<first_name_fa>کمال</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نبی اللهی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>k.nabiollahi@uok.ac.ir</email>
	<code>10031947532846006164</code>
	<orcid>10031947532846006164</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>University of Kurdistan, Sanandaj</affiliation>
	<affiliation_fa>دانشگاه کردستان، سنندج</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
